BSPLM - 1195 DISPERSANT POLYMER
- MSDS: BSPLM
- Manufacturer: NALCO CHEMICAL CO WATERGY GROUP
- Product Name: 1195 DISPERSANT POLYMER
- National Stock Number: 6850-00F031941
Product Identification
Product ID:1195 DISPERSANT POLYMER
MSDS Date:07/16/1991
FSC:6850
NIIN:00F031941
MSDS Number: BSPLM
Responsible Party
NAPERVILLE, IL 60563-1198
US
Emergency Phone: 708-920-1510
Info Phone: 708-305-1000
Preparer: RICKY A STACKHOUSE
Cage: 89524
Contractor
Telephone: (630) 305-1000
Cage: 89524
Ingredients
BENZOTRIAZOLE
CAS: 95-14-7
RTECS: DM1225000
Fraction By Weight: 1-5%
PHOSPHONATES
ACRYLAMIDE/ACRYLATE POLYMER
9.2-9.7
RTECS: 9999999WG
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: MODERATE IRRITATION. SKIN: MILD,
SHORT-LASTING IRRITATION.
Explanation of Carcinogenicity:NONE
First Aid
First Aid:EYES: IMMEDIATELY FLUSH FOR AT LEAST 15 MINS WHILE HOLDING
EYELIDS OPEN. CALL A PHYSICIAN AT ONCE. SKIN: WASH THOROUGHLY
W/SOAP & WATER & RINSE AT ONCE. CALL A PHYSICIAN. INGESTION: DON'T
INDUCE VOMIT ING. GIVE WATER. CALL A PHYSICIAN. INHALATION: REMOVE
TO FRESH AIR. TREAT SYMPTOMS. CALL A PHYSICIAN. OBTAIN MEDICAL
ATTENTION IN ALL CASES. SEE SUPP.
Fire Fighting
Flash Point Method:PMCC
Flash Point:>200F
Extinguishing Media:WOULD NOT BE EXPECTED TO BURN UNLESS ALL WATER IS
BOILED AWAY. REMAINING ORANICS MAY BE IGNITABLE. USE WATER TO COOL.
Unusual Fire/Explosion Hazard:MAY EVOLVE NITROGEN OXIDE & SULFUR OXIDE
UNDER FIRE CONDITIONS. IF THE WATER IS DRIVEN OFF, THE REMAINING
ORGANICS MAY BE IGNITABLE.
Accidental Release
Spill Release Procedures:SMALL: CONTAIN W/ABSORBENT MATERIAL. SHOVEL
RECLAIMED LIQUID & ABSORBENT INTO RECOVERY OR SALVAGE DRUMS FOR
DISPOSAL. LARGE: DIKE TO PREVENT FURTHER MOVEMENT & RECLAIM INTO
RECOVERY OR SALVAGE DRUMS O R TANK TRUCK FOR DISPOSAL.
Handling
Handling and Storage Precautions:EMPTY CONTAINERS MAY CONTAIN RESIDUAL
PRODUCT. DON'T REUSE CONTAINER UNLESS PROPERLY RECONDITIONED.
Other Precautions:AVOID CONTACT W/SKIN, EYES, OR CLOTHING. DON'T TAKE
INTERNALLY.
Exposure Controls
Respiratory Protection:IF SIGNIFICANT VAPORS, MISTS OR AEROSOLS ARE
GENERATED, WEAR A NIOSH APPROVED OR EQUIVALENT RESPIRATOR. FOR A
LARGE SPILL, ENTRY INTO LARGE TANKS, VESSELS OR ENCLOSED SMALL
SPACES W/INADEQUATE VENTILA TION, USE A PRESSURE DEMAND SCBA.
Ventilation:GENERAL
Protective Gloves:IMPERMEABLE
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:EYE WASH FOUNTAIN, SAFETY SHOWER
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
NOTE TO PHYSICIAN: BASED ON THE INDIVIDUAL REACTIONS OF THE PATIENT,
THE PHYSICIAN'S JUDGMENT SHOULD BE USED TO CONTROL SYMPTOMS &
CLINICAL CONDITION. IF UNCONSCIOUS, HAVING TROUBLE BREATHING OR IN
CO NVULSIONS, DON'T INDUCE VOMITING OR GIVE WATER. PROBABLE MUCOSAL
DAMAGE MAY CONTRAINDICATE THE USE OF GASTRIC LAVAGE.
Chemical Properties
Boiling Pt:B.P. Text:212F
Melt/Freeze Pt:M.P/F.P Text:20F
Spec Gravity:1.10-1.16
pH:3-4
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR BRIGHT YELLOW LIQUID
Stability
Stability Indicator/Materials to Avoid:YES
ALKALINE MATERIALS, CYANIDES, SULFIDES, HYPOCHLORITES, CHLORITES.
Hazardous Decomposition Products:CO, CO2, NITROGEN OXIDE.
Disposal
Waste Disposal Methods:IF PRODUCT BECOMES A WASTE, IT DOES NOT MEET THE
CRITERIA UNDER THE RCRA ACT. AS A NON-HAZARDOUS LIQUID WASTE,
SOLIDIFY W/STABILIZING AGENTS BEFORE DISPOSAL TO AN INDUSTRIAL
WASTE LANDFILL. CAN ALSO BE DEEP WELL INJECTED
IAW/LOCAL/FED/STATE REGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.